Image
image
image
image


Hui Cyclorama Floods...


220-240V: 200W - 800W
120V: 100W - 1000W

Lifting stage and studio colour washes to new 3_year_warranty.gifheights.

The Hui Cyc gives you light where you want it, in a visually even, controlled wash, each luminaire’s beam blending seamlessly – the hallmark of Selecon cyc luminaires. No distracting spill light to provide unwanted illumination.

NB: In Russia the Hui range is known as the Helia range.

HUI range - EDDY Award for 2005 Lighting Product of the Year selected by a group of both young and veteran designers working in theatre, special events, dance and concerts.

The Award citation makes note of:
"Selecon has taken up the task of re-thinking the cyc light and the result is their HUI cyc, a favorite with our judges. “The design of the fixture is well thought-through and addresses many of our issues with cyc light strips (such as on-site configuration of rigid, low-profile ground rows, safety glass screens, durable construction, configurable connector panels, and more.),” says one judge.

One of the key features the judges liked about the HUI cyc was the heat exhaust/control system, which results in a much longer filter life; another high point was its aforementioned use as a ground row, simply by reversing the color cassette and the use of screw jack feet for adjustment."


Selecon Heat Removal System

Selecon's Cyc, Flood and Groundrow ranges have a well-deserved reputation for delivering life up to double that of some other cyc floods.

Further developments of the Selecon heat exhaust management system has resulted in the Hui and Lui delivering industry-leading filter life for their class and size.

The Selecon colour frame for the Hui, Lui and Aurora ranges gently clamps the plastic filter while holding the frame away from the luminaire body to reduce (+20°) the transference of the heat from the luminaire into the frame and plastic filter.

High performance 220-240V 800W studio lamps can be used in very compact luminaires with acceptable filter life.


Specifications  
Colour Frame Size: 265mm x 203mm / 8” x 10 3/8”
Accessories: 4-door barndoor, joiner set (2 of) Hui slot locks, spare colour frame
Weight: Single: 4.1kg /  9lb
3-way batten:  10.7kg / 23lb 5oz
4-way batten:  14kg / 31lb
Certification: CE, ETL / cETL listed to UL1575


Features
  • EXTRUDED ALUMINIUM REFLECTORS ENSURE the precise specifications of the asymmetric shape and guaranteed performance from luminaire to luminaire.
  • SELECON'S HEAT REMOVAL SYSTEM, protects and maximises your colour filter life.
  • SMOOTH, WELL-CONTROLLED BEAM.
  • MAKE YOUR OWN BATTENS using the Hui slot lock joint system that allows a number of units to be ‘locked’ together.
  • ROBUST CONSTRUCTION designed to withstand the most gruelling rental and production work.
  • CABLING/CONNECTOR OPTIONS – choice of either 1.0m/3ft cable tails or multi-connector models which includes options for in/out cable tails; all industry connectors and socket outlets for unused multi-circuits.
  • RELAMP WITHOUT REMOVING THE FILTER OR BREAKING FOCUS.
  • COLOUR FILTER HOLDER IS HELD CAPTIVE by a spring-hinged extruded cover that also blocks unwanted light spill.
  • SAFE WITH MAINS POWER DISCONNECT – microswitches isolate the mains supply (phase and neutral) when opening, preventing the insertion of a lamp into a live socket.
  • SAFETY GLASS ensures that in the unlikely event of a lamp exploding, the remains are held captive within the luminaire.
  • SHAPE THE BEAM, CONTAIN GLARE with the 4-door barndoor accessory.
  • CYC TO GROUNDROW conversion.
  • LUMINAIRE SHIPPED with colour frame, suspension bolt set and short form instruction sheet.
    NB: lamps are not supplied, please specify your requirements with your order.
Lamps

Important: In the 220-240V market the Hui range = maximum 800W with the Lui range providing the next step up to the 1000W lamp.
In the 120V market the Hui range = maximum 1000W.

220-240V
Lamp socket : R7, 118mm linear halogen lamps
120V
Lamp socket : R7, 4 11/16” linear halogen lamps
200W K11
2000hrs average life
300W  EHZ   
2000hrs average life
300W K9
2000hrs average life
300W  EHM   
2000hrs average life
500W K1
200hrs average life
500W  FDN   
400hrs average life
800W P2/11
150hrs average life
500W  FCL   
2000hrs average life
  750W  EMD   
400hrs average life
  750W  EJG   
400hrs average life
  1000W  FHM   
300hrs average life
  1000W  FCM   
300hrs average life


Performance information, size diagrams and order codes are detailed in the Hui Cyc Specification Sheets.

spacer prod-hui-cyc.jpg



 
12HUICYC3_Hui_Cyc_3_batten.jpg
 
12HUICYC4_Hui_Cyc_4_batten.jpg


 


Aurora_cyc_airflow.jpg














 


   
Hui_locking.jpg
Hui slot lock joint system....


to create your own battens. Download the instructions here.

hui_battens.jpg
   
hui_G_unit.JPG
Gland cabling
   
Hui_open.jpg
Relamping and automatic mains power disconnection
   
Easy access to colour filter hui_filter.JPG
   
hui_barndoor.jpg
Barndoor accessory



  
CYC = GROUNDROW
 
To convert a cyc to a groundrow, simply reverse the colour cassette by removing the two screw pivot hinges.


HUI_screw_pivot.jpg HUI_ground_row_screw_pivot.jpg



image
image