Image
image
image
image


Hui Groundrow...


220-240V: 200W - 800W
120V: 100 - 1000W

The Hui Groundrow range is the Hui cyc luminaire inverted to operate from the base of the cyc or back cloth.

3_year_warranty.gif
The distribution is a visually even, controlled wash with each luminaire's beam blending seamlessly - the hallmark of Selecon cyc/groundrow luminaires.
 
Changing a Hui Cyc luminaire to groundrow operation is simple - removing the colour cassette end hinge screw (M6 x 30 Philips head, machine screw) at each end of the luminaire, reversing the cassette and re-attaching.
 
This ensures the best performance, filter life and allows adjustable screw feet (Order Code: 15HLGDSF ) to be fitted to adjust the angle of the luminaire to the cloth.


Selecon Heat Removal System

Selecon's Cyc and Flood ranges have a well-deserved reputation for delivering life up to double that of some other cyc floods.

Further developments of the Selecon heat exhaust management system has resulted in the Hui and Lui delivering industry-leading filter life for their class and size.

The Selecon colour frame for the Hui, Lui and Aurora ranges gently clamps the plastic filter while holding the frame away from the luminaire body to reduce (+20°) the transference of heat from the luminaire into the frame and plastic filter.

High performance 220-240V 800W studio lamps can be used in very compact luminaires with acceptable filter life.


Specifications  
Colour Frame Size: 265mm x 203mm / 8” x 10 3/8”
Accessories: Joiner set (2 of) Hui slot locks, spare colour frame
Weights: Single: 4.1kg /  9lb
3-way batten:  10.7kg / 23lb 5oz
4-way batten:  14kg / 31lb
Certification: CE, ETL / cETL listed to UL1575

Features
  • EXTRUDED ALUMINIUM REFLECTORS ENSURE the precise specifications of the asymmetric shape and guaranteed performance from luminaire to luminaire.
  • SELECON'S HEAT REMOVAL SYSTEM, protects and maximises your colour filter life.
  • SMOOTH, WELL-CONTROLLED BEAM.
  • MAKE YOUR OWN BATTENS using the Hui slot lock joint system that allows a number of units to be ‘locked’ together.
  • ROBUST CONSTRUCTION designed to withstand the most gruelling rental and production work.
  • CABLING/CONNECTOR OPTIONS – choice of either 1.0m / 3ft cable tails or multi-connector models which includes options for in/out cable tails; all industry connectors and socket outlets for unused multi-circuits.
  • RELAMP WITHOUT REMOVING THE FILTER OR BREAKING FOCUS.
  • COLOUR FILTER HOLDER IS HELD CAPTIVE by a spring-hinged extruded cover that also blocks unwanted light spill.
  • SAFE WITH MAINS POWER DISCONNECT – microswitches isolate the mains supply (phase and neutral) when opening, preventing the insertion of a lamp into a live socket.
  • SAFETY GLASS ensures that in the unlikely event of a lamp exploding, the remains are held captive within the luminaire.
  • SHAPE THE BEAM, CONTAIN GLARE with the 4-door barndoor accessory.
  • CYC TO GROUNDROW conversion.
  • LUMINAIRE SHIPPED with colour frame, suspension bolt set and short form instruction sheet.
    NB: lamps are not supplied, please specify your requirements with your order.
Lamps

In the 220-240V market the Hui range = maximum 800W with the Lui range providing the next step up to the 1000W lamp.
In the 120V market the Hui range = maximum 1000W.


220-240V
Lamp socket : R7, 118mm linear halogen lamps
120V
Lamp socket : R7, 4 11/16” linear halogen lamps
200W K11 2000hrs average life 300W  EHZ    2000hrs average life
300W K9 2000hrs average life 300W  EHM    2000hrs average life
500W K1 200hrs average life 500W  FDN    400hrs average life
800W P2/11 150hrs average life 500W  FCL    2000hrs average life
  750W  EMD    400hrs average life
  750W  EJG    400hrs average life
  1000W  FHM    300hrs average life
  1000W  FCM    300hrs average life

Performance information, size diagrams and order codes are detailed on the Hui Groundrow Specification Sheets.

spacer prod-hui-groundrow.jpg

hui_groundrow_1.jpg


Aurora_cyc_airflow.jpg

   
Hui_locking.jpg
Hui slot lock joint system....


to create your own battens.

Download the instructions here.
hui_battens.jpg
   
Hui_open.jpg
Relamping and automatic mains power disconnection
   
Easy access to colour filter hui_filter.JPG
   